           UL94 flame retardant rating test

          UL94 flame retardant rating is the most widely used material flame retardant performance evaluation standard. It is used to evaluate the ability of materials to extinguish after being ignited and is a commonly used standard for daily testing of material flame retardancy. There are multiple evaluation methods for UL94 based on the combustion rate, combustion time, droplet resistance, and whether the droplets burn after ignition of the material.

           

          UL94 has a total of 12 levels:

           

          HB, V-0, V-1, V-2, 5VA, 5VB, VTM-0, VTM-1, VTM-2, HBF, HF1, HF2

           

          Among them, VTM-0, VTM-1, and VTM-2 are suitable for plastic film, while HBF, HF1, and HF2 are suitable for foam materials

           

          The level testing plan is as follows:

          1) HB level: Horizontal Burning Test

          2) V0-V2 level: Vertical Burning Test

          3) 5VA/5VB: 5V level fire test 500w (125 mm) vertical burning test

          4) RP Class: Radiant Panel Flame Spread Test

          5) VTM0-VTM2: Thin Material Vertical Burning Test

          6) HF1-HF2: Horizontal Burning Foam Material Test

           

          The specific testing requirements for UL94 are as follows:

           

          HB: Flame retardant rating in UL94 standard. Require a combustion rate of less than 40 millimeters per minute for samples with a thickness of 3 to 13 millimeters; Samples less than 3 millimeters thick have a combustion rate of less than 70 millimeters per minute; Or extinguish before the 100mm mark.

           

          V-0: After conducting two 10 second combustion tests on the sample, the residual flame and residual flame will extinguish within 30 seconds. Dropping particles cannot ignite cotton.

           

          V-1: After conducting two 10 second combustion tests on the sample, the residual flame and residual flame will extinguish within 60 seconds. Dropping particles cannot ignite cotton.

           

          V-2: After two 10 second combustion tests on the sample, the residual flame and residual flame will extinguish within 60 seconds. Dripping particles can ignite cotton.

           

          5VB: After conducting five 5-second combustion tests on the sample, the residual flame and residual flame will extinguish within 60 seconds. Dropping particles cannot ignite cotton. For block samples, it is allowed to be burned through.

           

          5VA: After conducting five 5-second combustion tests on the sample, the residual flame and residual flame will extinguish within 30 seconds. Dropping particles cannot ignite cotton. It is not allowed to burn through block samples.

           

          Common UL94 testing methods

          1. Horizontal Combustion Test (HB)

          2. 50W vertical combustion test

          3.500W vertical combustion test

           

          UL 94 Flame Retardant Rating Criteria

          1. UL94 horizontal combustion judgment conditions


          Burning rate

          Flame retardant rating

          Sample thickness 3-13mm

          40mm/min

          HB

          Sample thickness 3mm

          75mm/min

          HB

          The flame goes out before the marking   line

          =0 mm/min

          HB

          2. UL94 vertical combustion judgment conditions

          Judgment condition

          V-0

          V-1

          V-2

          Spontaneous combustion time after   applying flames

          10

          30

          30

          Total self ignition time (s)

          (10   spontaneous combustion times)

          50

          250

          250

          Spontaneous combustion after the second   flame application

          +Crimson time (s)

          30

          60

          60

          Droplets ignite cotton

          no

          no

          yes

          Burn to fixture (sample completely   burned)

          no

          no

          no

          3. UL94 500w vertical combustion judgment conditions


          5VA

          5VB

          Any sample spontaneously ignites after 5   flame applications+Crimson time (s)

          60

          60

          Droplets ignite cotton

          no

          no

          Sample perforation ( 3mm)

          no

          yes

           

          Please consult NormalTCI for specific questions

          National Unified Service Hotline: 400-6177-880

          Email [email protected]

          Copyright @ 2015 NORMAL (HANGZHOU) TESTING & CERTIFICATION CO., LTD.  

          Tell:+86-571-28906690  E-mail:[email protected]  Service Hotline:400-6177-880  Fax:+86-571-28867000

          If you have any comments on the website, please email to:[email protected]

            <cite id="ijzde"><source id="ijzde"></source></cite>

            • <blockquote id="ijzde"><p id="ijzde"></p></blockquote>
                操美女的网站 | 日本三级韩国三级美三级91 | 国产久一色综合久久精品国 | 中文字幕第32页 | 国内自拍视频网 | 嫩草午夜福利电影 | 西川结衣绝顶喷汗88av | aaaaaa黄色片 | 娇妻在朋友的胯下娇吟h | 国产精品4 |